Analog Pressure Sensors
March 2006
 Print this page

New analog pressure sensors have a working range of 0-300Pa (Pascal), 0-3000Pa and 0-6000Pa. They utilize a supply voltage of 5 to 15 Vcc with maximum supply current of 6 mA.

Operating temperature for the sensors is -10 degrees celcius to +85 degrees celcius and temperature sensitivity is 0.04 percent FS/K. Total accuracy error (linearity, hysteresis, repeatability) is 1.6 percent FS. BITRON Industrie S.p.A., www.bitron-ind.com