ASHRAE Publishes 2013 IAQ Standard
Nov 12, 2013
 Printable format
 Email this Article
 Search

The 2013 version of ASHRAE's indoor air quality standard was published with several revisions to help users better meet its requirements.

ANSI/ASHRAE Standard 62.1-2013, Ventilation for Acceptable Indoor Air Quality, sets minimum ventilation rates and other requirements for commercial and institutional buildings.

The 2013 standard combines the 2010 standard and 10 published addenda to that edition. Specific information on the contents of each addendum and approval dates for each addendum are included in Informative Appendix J at the end of the standard.

"The 2013 version of Standard 62.1 continues the trend of increasing clarity while adding flexibility," said Roger Hedrick, Standard 62.1 committee chair. "These changes will allow designers and building operators to meet the requirements of the standard and provide adequate ventilation airflow to occupants while reducing excess ventilation and the associated energy consumption."

The 2013 edition includes a number of changes that remove inconsistencies within the standard and improve clarity.

Significant changes include:

* Table 6-2, Zone Air Distribution Effectiveness is modified to increase the ventilation effectiveness of underfloor air distribution systems that meet certain conditions.
* Requirements for the quality of water used in humidification systems are modified and clarified.
* Building level pressurization requirements were clarified, including adding a definition of "exfiltration."
* A performance alternative to the prescriptive exhaust rates is added. This approach differs from the Indoor Air Quality Procedure, the existing performance-based method for setting supply ventilation rates, in that monitoring of the concentrations of contaminants of concern is required and provides the basis for control of exhaust flow rates.
* Some changes to the ventilation rates and space types in Table 6-1 are made. These add refrigerated warehouses and change the ventilation rate for sports related spaces to include a per occupant component which then allows the use of demand controlled ventilation in these spaces.
* The filtration requirement on air entering wetted cooling coils has been modified to change the MERV rating from 6 to 8. This change will reduce potential for particulate deposition on the coils that could lead to biological or other contamination on the coils.
* Toilet exhaust air that is cleaned to Class 1 may be recirculated.

The new standard can be purchased from ASHRAE at:
www.ashrae.org/bookstore

Back to Daily News

 

Daily News

...........................................................

Oct 29, 2014: Canadian HVAC/R wholesaler sales up 5.3% so far in 2014

Oct 29, 2014: Russian steel agreement revoked

Oct 29, 2014: September 2014 Housing Starts in Canada

Oct 28, 2014: HVAC/R contractors remain optimistic about short-term growth

Oct 23, 2014: Whirlpool Corporation to Showcase Resource-Efficient Technologies at Greenbuild

More Daily News>>

RSS Feeds
.........................................................
Appliance Industry
Market Research

...........................................................

November 2014: U.S. Appliance Industry: Market Value, Life Expectancy & Replacement Picture 2014
October 2014: Portrait of the European Appliance Industry
September 2014: Appliance Industry Focus: HVAC
June 2014: Appliance Magazine Market Insight: April 2014




 
Contact Us | About Us | Subscriptions | Advertising | Home
UBM Canon © 2014  

Please visit these other UBM Canon sites

UBM Canon Corporate | Design News | Test & Measurement World | Packaging Digest | EDN | Qmed | Plastics Today | Powder Bulk Solids | Canon Trade Shows